Back to Top

Hi, Guest!

  LOKASI :  Kabupaten Tangerang

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • Pulse Oximeter CMS 50F

Pulse Oximeter CMS 50F

Update Terakhir
:
16 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
110 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Pulse Oximeter CMS 50F

Major Features   Small in volume light in weight and convenient in carrying   Operation of the product is simple , low power consumption   Operation menu for the function setting   SpO2 value display   Pulse rate value display, bar graph display   Pulse waveform display   With PI display   The display mode can be changed   Screen brightness can be changed   A pulse rate sound indication   Multi-time segment storage   With measured data overruns limits and low-voltage alarm function the upper/ down alarm range is adjustable   Battery capacity indication   Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage , and with alarm function   With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers   Real-time data can be transmitted to computers   Connected with an external oximeter probe   Power-off: long press power button to turn off the device   Wireless communication function CMS50IW Main performance Display Mode: 1.5" Color OLED display Screen Resolution: 128* 128 SpO2 Measuring Range: 0% ^ 100% , ( the resolution is 1% ) . Accuracy: 70% ^ 100% : ± 2% , Below 70% unspecified. PR Measuring Range: 30bpm^ 250bpm, ( the resolution is 1bpm) Accuracy: ± 2bpm or ± 2% ( select larger) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4% . SpO2 error is ± 4% , pulse rate error is ± 2 bpm or ± 2% ( select larger) . Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1% . Power Consumption: less than 100mA Voltage: DC 3.6V^ 4.2V Power Supply: Voltage 3.7 rechargeable lithium battery × 1 Battery Working Hour: 10 hours Battery working life: Charge and discharge no less than 500 times. Safety Type: Interior Battery BF Type Accessories Sell in standard:   A user manual   A data line   A disk ( PC software)   An adult-oximeter probe   Two One-off adhesive SpO2 probe   A power adapter  GTM41076-0605; CMS0105 Sell in addition:   Other oximeter probe( Refer to probe application instruction for details and notice renewal Physical Identity Dimension: 63( L) × 55( W) × 15( H) mm Weight: About 45g ( with the lithium battery* 1)
Tampilkan Lebih Banyak